New!
Generis - dw4Q Smart Drive
The Ultimate Systems Drive

Home » AC Drives » Generis – dw4Q Smart Drive

Mobile Users:
Continue tapping the rightmost menu item to reveal Dimensions, Downloads, Images, and more >>

Overview

4-Quadrant Regenerative AC Drive
drive.web distributed Control
Near Unity Power Factor & Full Torque from zero speed
Ultra-low harmonics
UL & STO (Pending)
IP20 Packaging


- 10 TO 30 HP -

Artificial lifts
Converting Lines
Energy generation / transfer & recovery
Extrusion & Molding
Flywheels
Low harmonic or regen fans
Low harmonic or regen pumps
Material handling equipment
Packaging
Printing & Coating
Process control
Pumped hydro
Textiles
Wind turbines
Winding / Unwinding



High performance AC vector drives for coordinated drive systems and precision machine control.

Features

  • Open-loop V/f and closed-loop vector control for induction motors
  • Constant and quadratic torque modes with current loop autotune
  • High-precision closed-loop speed accuracy (0.02%)
  • Four-quadrant regenerative operation
  • 380–500Vac, three-phase, 50/60Hz input
  • Output frequency up to 200Hz
  • Full featured programmable control
    • Graphical Function Block programming
    • drive.web distributed control
    • Built-in PID, advanced math, winder, motion and position control
  • Comprehensive diagnostics and monitoring
    • Motor current, voltage, speed and power
    • AC supply voltage and frequency
    • Heatsink and motor temperature (PT100 input)
    • Run and powered hours
  • Integrated communications
    • drive.web smart Ethernet
    • Modbus TCP/IP and Ethernet/IP
    • USB-C
    • Optional PROFIBUS, PROFINET, DeviceNet, EtherCAT, Modbus and CAN/CANopen
  • Flexible I/O configuration with analog and digital inputs/outputs
  • Dual incremental encoder support (5V / 12V / 24V selectable)
  • Comprehensive protection including thermal, over-current, stall and power loss protection
  • IP20 enclosure, air-cooled with temperature-controlled fans
  • 0–50°C operating temperature (derate above 40°C)
  • Integrated operator station with 2 × 20 character backlit LCD, local/remote control and dedicated Run/Jog/Stop keys
  • CE compliant; UL pending; STO Pending

dw4Q - Smart AC Drive



The drive.web automation technology uses distributed control over Ethernet to provide cost effective systems integration for systems of any size or complexity.

Specifications

Supply Voltage380 – 500Vac, Three-Phase
Supply Frequency50 / 60 Hz
RegenerationFour-Quadrant Regenerative
Auxiliary SupplyOptional 24VDC Input
EMC FilterInternal (Standard)
Power Rating10, 15, 20, 25, 30 HP
(7.5, 11, 15, 18.5, 22 kW)
Current Rating – Normal Duty18, 26, 35, 44, 52A — 110% overload for 30 seconds
Current Rating – Heavy Duty15, 22, 30, 37, 44A — 150% overload for 30 seconds
Output VoltageVout ≤ 0.86 × Vin
Maximum Output Frequency200 Hz
Speed Accuracy2% (Open-Loop V/f)
0.02% (Closed-Loop Vector)
Motor CompatibilityInduction Motors
Control ModesOpen-Loop V/f
Closed-Loop Vector
Torque ModesOpen-Loop Constant Torque
Open-Loop Quadratic Torque
Speed ControlYes
AutotuneCurrent Loop Autotune
Programmable ControlFull Featured
Functions IncludedAnalog Logic
PID Controllers
Advanced Math
Winder Control
Motion Control
Position Control
Motor MonitoringCurrent
Voltage
Speed
Power
AC Supply MonitoringVoltage
Frequency
Temperature MonitoringHeatsink Temperature
Motor Temperature (External Sensor Required)
Input MonitoringUser Input Voltages
Runtime MonitoringRun Hours
Powered Hours
Standard Interfacesdrive.web Smart Ethernet
Modbus TCP/IP
Ethernet/IP
USB-C
Optional NetworksPROFIBUS
PROFINET
DeviceNet
EtherCAT
Modbus
CAN / CANopen
All Major Industrial Networks
ProgrammingGraphical Function Block Programming
drive.web Distributed Control
Analog Inputs3 × ±10V configurable reference supplies (10mA max)
1 × 4–20mA or ±10V configurable reference
Analog Outputs2 × configurable, ±10V range
Digital Inputs24V logic, current sinking
4 dedicated: Run, Stop, Jog, Coast Stop
Additional configurable inputs
Digital Outputs24V logic, current sourcing (400mA max)
5 configurable
Relay Outputs2 configurable, 240VAC volt-free contacts
Encoder InputsSingle or Dual Incremental
A, B, Marker
Differential or Single-Ended
5V / 12V / 24V (Software Selectable)
Motor Temperature Input1 × PT100 (External Sensor Required)
Protection FeaturesThermal Fold-Back
Instantaneous Over-Current
Motor Over-Temperature
Heatsink Over-Temperature
AC Power Loss
AC Line Sync Loss
Stall Protection
Standstill Logic
Fan Fail
Digital/Analog Output Short-Circuit
Digital/Analog Input Over-Voltage (to 30VDC)
Operating Temperature0 – 50°C (Derate above 40°C)
Storage Temperature-25°C to +55°C
Ingress ProtectionIP20
CoolingAir-Cooled with Temperature-Controlled Fans
MountingKeyhole Slot Mounting
Control ConnectionsTwo-Part Control Connections
ComplianceEN 61800-5-1:2007 (CE – Low Voltage Directive)
EN 61800-3:2017 (CE – EMC)
EN 61800-5-2:2017 (STO Pending)
UL 61800-5-1 (UL Pending)

Dimensions

Frame Size12
ProtectionIP20IP20
Height22.7”
(576 mm)
22.8”
(578 mm)
Width 10.4”
(264 mm)
10.4”
(264 mm)
Depth9.2”
(234 mm)
11.4”
(289 mm)
Weight48.5 lbs
(22 kg)
55.1 lbs
(25 kg)

Images

Downloads


To download P2 Series manuals, drawings, and more, please make a selection from the dropdown menu below:
Filename / LinkSize
bardac-generis-brochure-1.3-web.pdf5.35 Mb
Filename / LinkSize
Generis 5x7 sign-v3.1.pdf1.05 Mb

This content is password protected. Please fill out the form below or enter the password to access.

OR

This content is password protected. Please fill out the form below or enter the password to access.

OR

This content is password protected. Please fill out the form below or enter the password to access.

OR

This content is password protected. Please fill out the form below or enter the password to access.

OR

This content is password protected. Please fill out the form below or enter the password to access.

OR