P2 Series
SYSTEMS VECTOR DRIVES

Home » AC Drives » P2 Series – Systems Vector Drives up to 400HP

Mobile Users:
Continue tapping the rightmost menu item to reveal Dimensions, Downloads, Images, and more >>

Overview

High Performance AC Drives
Induction & PM Motor Control
230, 460, 500, 600 volt models


- 1 TO 400 HP -


NEMA12 Packaging | 7.5 - 400HP
Through Panel Mount Option
NEMA 4X to 10HP (indoor rated)

Printing Presses
Extrusion & Coating Lines
Automated Assembly
Indexing & Registration
Winders & Web Tension
Material Handling
Cranes & Hoists
Textiles & Fibres
Metals Industry
Paper & Cement Mills
Mining



Six P2 Series AC systems vector drives of varying sizes. Fractional through 250HP | Sizes 2, 3, 4, 5, 6, 7


High performance AC vector drives for coordinated drive systems and precision machine control.

Features

  • Multiple Modes:
    • Closed Loop Vector for high performance
    • Open loop PM Motor control
    • Sensorless vector & V/Hz control
    • Open Loop PM Vector Control
  • Up to 200% torque at zero speed
  • Sensorless speed regulation better than 1%
  • Torque control
  • DC bus sharing
  • Safe Torque Off function
  • Output to 500Hz (V/F Mode), 100Hz (Vector Mode)
  • Built-in 100% rated DB transistor up to 400HP
  • Integral PI controller
  • drive.web savvy function block programming
  • Silent running with up to 32KHz switching
  • 200% starting torque
  • Bipolar 12 bit analog input (isolated +/-10V or 4-20mA)
  • ModbusRTU, RS485 port (RJ-45)
  • CANopen port
  • Filters & DC chokes 25-250 HP
  • Single phase input up to 125 HP
  • Power loss ride through
  • Process control options
  • Programmable I/O
  • Hours run log & trip log
  • Cartridge fans for easy maintenance (NEMA12 drives)
  • UL, CE, C-Tick on all models
  • Options:
    • Encoder feedback
    • Additional basic & smarty I/O options
    • EIP, Modbus TCP/IP, Profibus, DeviceNet, BACnet
    • Memory stick with bluetooth interface
    • Remote keypad
    • 2Khz output in V/Hz mode
    • Bright TFT display
    • Through panel mount for NEMA 12 versions


P2 Series ... Smart AC Drives!



The drive.web automation technology uses distributed control over Ethernet to provide cost effective systems integration for systems of any size or complexity.

- savvyPanel Touch -

Easy, high resolution, NEMA4, touch screen operator stations.

Also run savvyPanel on PCs or roam on iOS devices!

- drive.web smart automation -

Powerful programmable control functions
Peer-to-peer over Ethernet
Smart iPad or touch screen PC operation
Easy system wide Internet access

Specifications

Supply Voltage200 – 240 ± 10%
380 – 480 ± 10%
500 – 600 ± 10%
Supply Frequency48 – 62 Hz
Displacement PF> 0.98
Phase Imbalance3% Maximum allowed
Inrush Current< Rated current
Power Cycles120 per hour max, evenly spaced
Power Output230V, 1-ph in: 1-3 HP (0.75-2.2 kW)
230V, 3-ph in: 1-100 HP (0.75-75 kW)
400V, 3-ph in: 0.75-200kW
460V, 3-ph in: 1-400 HP
600V, 3-ph in; 1-150 HP
Overload Capacity150% for 60 secs, 200% for 4 secs.
Output Frequency0-500Hz in V/Hz mode (0.1 Hz res) (optional 2KHz)
0-100Hz in vector mode
TemperatureStorage: -40°C to 60°C
Operating:

  • -10°C to 40°C (IP40, IP55 & IP66)
  • -10°C to 50°C (IP20)
AltitudeUp to 1000m ASL without de-rating
Up to 2000m Max UL Approved
Up to 4000m Max (non UL)
Above 1000m, de-rate 1% per 100m
Humidity95% non-condensing
Ingress ProtectionIP20 – Frame sizes 2 & 3
IP40 (NEMA 1) – Frame size 8
IP55 (NEMA 12) – Frame sizes 4 to 7
IP66 (NEMA 4X) – Optional sizes 2 & 3
KeypadStandard: Built-in keypad
Optional: Remote keypad
Optistick memory stick
USB or Ethernet Optiondrive.web savvy software
DisplayBright Red LED (IP20 Enclosure)
Bright Green OLED text (NEMA12, NEMA4X, and Size 8 Enclosures)
Control ModesClosed Loop (encoder) speed control
Closed Loop (encoder) torque control
Open Loop PM vector control
Sensorless vector speed control
V/F Voltage vector
Energy optimized V/F
Modulation4 – 32 kHz effective
Stop ModeRamp to stop – adjustable 0.1-600 secs
Safe Torque Off mode
BrakingMotor flux braking (DC injection)
Built in brake transistor
Skip FrequencySingle point user adjustable
Analog Setpoint Control0-10v, 10-0v, ±10v
0-20mA, 20-0mA, 4-20mA, 20-4mA
Digital Setpoint ControlKeypad
ModbusRTU
CANopen
AutomationOptional drive.web Ethernet distributed control + programmable control, extra i/o, operator stations
Communications Optionsdrive.web, ModbusTCP, EIP, DeviceNet, Profibus
Power Supply24VDC, 100mA short protected
10VDC, 5mA for setpoint potentiometer
Programmable Inputs3 x Digital 10 to 30 VDC, response < 4ms 2 x Analog/digital
Programmable Outputs2 x Analog, 0-10V, 0-20mA, 4-20mA
2 x Relay NO, 6A @ 250VAC, 5A @ 30VDC
PIDInternal PID with feedback display
Fault MemoryLast 4 trips stored with time stamp
Data LoggingCurrent, temperature, DC Bus volts prior to trip
Maintenance IndicatorService life monitor with user adjustable interval
MonitoringHours run
Resettable and non-resettable kWh meters
T2-ENCOD-IN Encoder feedback module
T2-OPORT-IN Remote keypad & display
T3-OPPAD-IN Remote keypad w/TFT display
Frame Size223345678
ProtectionIP20NEMA 4X
(IP66)
IP20NEMA 4X
(IP66)
NEMA 12
(IP55)
NEMA 12
(IP55)
NEMA 12
(IP55)
NEMA 12
(IP55)
IP20
Height (ins)8.7”10.1”10.3”12.2”17.7”21.3”34.1”50.4”40”
Height (mm)2212572613104505408651280995
Width (ins)4.4”7.4”5.2”8.3”6.8”9.3”13”13”19”
Width (mm)112188131211171235330330482
Depth (ins)7.3”9.4”8.1”10.5”9.9”10.7”13.0”14.2”19”
Depth (mm)185239205266252270330360480
Weight (lbs)410.67.71725.450.7121196.2282
Weight (kg)1.84.83.57.711.5235589128
P2 Series - AC Systems Vector Drives | Sizes 2, 5, and 7 to 250HP

Models & Ratings

Standard IP20 Packages

with EMC Filter & DB transistor

P2 Series - AC Systems Vector Drives - IP20 Package | Size 3 | to 15HP | 25 amps
ModelHPAmpsFrame Size
P2-22010-1HF4214.32
P2-22020-1HF42272
P2-22030-1HF42310.52
ModelHPAmpsFrame Size
P2-22010-3HF4214.32
P2-22020-3HF42272
P2-22030-3HF42310.52
P2-32050-3HF425183
P2-32075-3HF427.5243
ModelHPAmpsFrame Size
P2-24010-3HF4212.22
P2-24020-3HF4224.12
P2-24030-3HF4235.82
P2-24050-3HF4259.52
P2-34075-3HF427.5143
P2-34100-3HF4210183
P2-34150-3HF4215243
ModelHPAmpsFrame Size
P2-26010-3H04212.12
P2-26020-3H04223.12
P2-26030-3H04234.12
P2-26050-3H04256.52
P2-26075-3H0427.592
P2-36100-3H04210123
P2-36150-3H04215173
P2-36200-3H04220223
ModelMotor Output RatingDrive SizeOutput CurrentData sheet
200-240 V, 1-ph in
P2-22010-1HF42-T1 HP (0.75 kW)24.3 APDF
P2-22020-1HF42-T2 HP (1.5 kW)27 APDF
P2-22030-1HF42-T3 HP (2.2 kW)210.5 APDF
200-240 V, 3-ph in
P2-22010-3HF42-T1 HP (0.75 kW)24.3 APDF
P2-22020-3HF42-T2 HP (1.5 kW)27 APDF
P2-22030-3HF42-T3 HP (2.2 kW)210.5 APDF
P2-32050-3HF42-T5 HP (4 kW)318 APDF
P2-32075-3HF42-T7.5 HP (5.5 kW)324 APDF
P2-42100-3HF42-T10 HP (7.5 kW)430 APDF
P2-42150-3HF42-T15 HP (11 kW)446 APDF
P2-52020-3HF42-T20 HP (15 kW)560 APDF
P2-52025-3HF42-T25 HP (18.5 kW)572 APDF
P2-62030-3HF42-T30 HP (22 kW)6A90 APDF
P2-62040-3HF42-T40 HP (30 kW)6A110 APDF
P2-62050-3HF42-T50 HP (37 kW)6B150 APDF
P2-62060-3HF42-T60 HP (45 kW)6B180 APDF
380-480 V, 3-ph in
P2-24010-3HF42-T1 HP (0.75 kW)22.2 APDF
P2-24020-3HF42-T2 HP (1.5 kW)24.1 APDF
P2-24030-3HF42-T3 HP (2.2 kW)25.8 APDF
P2-24050-3HF42-T5 HP (4 kW)29.5 APDF
P2-34075-3HF42-T7.5 HP (5.5 kW)314 APDF
P2-34100-3HF42-T10 HP (7.5 kW)318 APDF
P2-34150-3HF42-T15 HP (11 kW)324 APDF
P2-44200-3HF42-T20 HP (15 kW)430 APDF
P2-44250-3HF42-T25 HP (18.5 kW)439 APDF
P2-44300-3HF42-T30 HP (22 kW)446 APDF
P2-54040-3HF42-T40 HP (30 kW)561 APDF
P2-54050-3HF42-T50 HP (37 kW)572 APDF
P2-64060-3HF42-T60 HP (45 kW)6A90 APDF
P2-64075-3HF42-T75 HP (55 kW)6A110 APDF
P2-64120-3HF42-T120 HP (75 kW)6B150 APDF
P2-64150-3HF42-T150 HP (90 kW)6B180 APDF
P2-64175-3HF42-T175 HP (110 kW)6B202 APDF
P2-84300-3HF42-T300 HP (200 kW)8370 APDF
P2-84300-3HR42-T300 HP (200 kW)8370 APDF
P2-84400-3HF42-T400 HP (250 kW)8480 APDF
P2-84400-3HR42-T400 HP (250 kW)8480 APDF
500-600 V, 3-ph in
P2-26010-3H042-T1 HP (0.75 kW)22.1 APDF
P2-26020-3H042-T2 HP (1.5 kW)23.1 APDF
P2-26030-3H042-T3 HP (2.2 kW)24.1 APDF
P2-26050-3H042-T5 HP (4 kW)26.5 APDF
P2-26075-3H042-T7.5 HP (5.5 kW)29 APDF
P2-36100-3H042-T10 HP (7.5 kW)312 APDF
P2-36150-3H042-T15 HP (11 kW)317 APDF
P2-36200-3H042-T20 HP (15 kW)322 APDF
P2-46250-3H042-T25 HP (18.5 kW)428 APDF
P2-46300-3H042-T30 HP (22 kW)434 APDF
P2-46400-3H042-T40 HP (30 kW)441 APDF
P2-56050-3H042-T50 HP (37 kW)554 APDF
P2-56060-3H042-T60 HP (45 kW)565 APDF

NEMA12 (IP55) Packages

with EMC Filter, DB transistor, DC Chokes

P2 Series - AC Systems Vector Drives - NEMA 12 Package | Size 4 to 30HP | 46 amps
ModelHPAmpsFrame Size
P2-42075-3HF4N7.5244
P2-42100-3HF4N10304
P2-42150-3HF4N15464
P2-52020-3HF4N20615
P2-52025-3HF4N25725
P2-62030-3HF4N30906
P2-62040-3HF4N401106
P2-62050-3HF4N501506
P2-62060-3HF4N601806
P2-72075-3HF4N752027
P2-72100-3HF4N1002487
ModelHPAmpsFrame Size
P2-44150-3HF4N15244
P2-44200-3HF4N20304
P2-44250-3HF4N25394
P2-44300-3HF4N30464
P2-54040-3HF4N40615
P2-54050-3HF4N50725
P2-64060-3HF4N60906
P2-64075-3HF4N751106
P2-64120-3HF4N1201506
P2-64150-3HF4N1501806
P2-74175-3HF4N1752027
P2-74200-3HF4N2002407
P2-74250-3HF4N2503027
P2-84300-3HF4N3003708
P2-84400-3HF4N4004808
ModelHPAmpsFrame Size
P2-46200-3H04N20224
P2-46250-3H04N25284
P2-46300-3H04N30344
P2-46400-3H04N40434
P2-56050-3H04N50545
P2-56060-3H04N60655
P2-66075-3H04N75786
P2-66100-3H04N1001056
P2-66125-3H04N1251306
P2-66150-3H04N1501506
ModelMotor Output RatingDrive SizeOutput CurrentData sheet
200-240 V, 3-ph in
P2-42075-3HF4N-T7.5 HP (5.5 kW)424 APDF
P2-42100-3HF4N-T10 HP (7.5 kW)430 APDF
P2-42150-3HF4N-T15 HP (11 kW)446 APDF
P2-52020-3HF4N-T20 HP (15 kW)560 APDF
P2-52025-3HF4N-T25 HP (18.5 kW)572 APDF
P2-62030-3HF4N-T30 HP (22 kW)690 APDF
P2-62040-3HF4N-T40 HP (30 kW)6110 APDF
P2-62050-3HF4N-T50 HP (37 kW)6150 APDF
P2-62060-3HF4N-T60 HP (45 kW)6180 APDF
P2-72075-3HF4N-T75 HP (55 kW)7202 APDF
P2-72100-3HF4N-T100 HP (75 kW)7248 APDF
380-480 V, 3-ph in
P2-44150-3HF4N-T15 HP (11 kW)424 APDF
P2-44200-3HF4N-T20 HP (15 kW)430 APDF
P2-44250-3HF4N-T25 HP (18.5 kW)439 APDF
P2-44300-3HF4N-T30 HP (22 kW)446 APDF
P2-54040-3HF4N-T40 HP (30 kW)561 APDF
P2-54050-3HF4N-T50 HP (37 kW)572 APDF
P2-64060-3HF4N-T60 HP (45 kW)690 APDF
P2-64075-3HF4N-T75 HP (55 kW)6110 APDF
P2-64120-3HF4N-T120 HP (75 kW)6150 APDF
P2-64150-3HF4N-T150 HP (90 kW)6180 APDF
P2-74175-3HF4N-T175 HP (110 kW)7202 APDF
P2-74200-3HF4N-T200 HP (132 kW)7240 APDF
P2-74250-3HF4N-T250 HP (160 kW)7302 APDF
P2-84300-3HF4N-T300 HP (200 kW)8370 APDF
P2-84300-3HR4N-T300 HP (200 kW)8370 APDF
P2-84400-3HF4N-T400 HP (250 kW)8480 APDF
P2-84400-3HR4N-T400 HP (250 kW)8480 APDF
500-600 V, 3-ph in
P2-46200-3H04N-T20 HP (15 kW)422 APDF
P2-46250-3H04N-T25 HP (18.5 kW)428 APDF
P2-46300-3H04N-T30 HP (22 kW)434 APDF
P2-46400-3H04N-T40 HP (30 kW)441 APDF
P2-56050-3H04N-T50 HP (37 kW)554 APDF
P2-56060-3H04N-T60 HP (45 kW)565 APDF
P2-66075-3H04N-T75 HP (55 kW)678 APDF
P2-66100-3H04N-T100 HP (75 kW)6105 APDF
P2-66125-3H04N-T125 HP (90 kW)6130 APDF
P2-66150-3H04N-T150 HP (110 kW)6150 APDF

NEMA 4X (IP66) Packages to 40 HP

Switched

with keypad, display, speed pot, power isolator switch,
FWD/OFF/REV switch

P2 Series - AC Systems Vector Drives - NEMA 4X (IP66) | Size 2 | Switched - version with keypad, display, speed pot, forward/off/reverse switch & power isolator switch
ModelHPAmpsFrame Size
P2-22010-1HF4B14.32
P2-22020-1HF4B272
P2-22030-1HF4B310.52
ModelHPAmpsFrame Size
P2-22010-3HF4B14.32
P2-22020-3HF4B272
P2-22030-3HF4B310.52
P2-32050-3HF4B5183
ModelHPAmpsFrame Size
P2-24010-3HF4B12.22
P2-24020-3HF4B24.12
P2-24030-3HF4B35.82
P2-24050-3HF4B59.52
P2-34075-3HF4B7.5143
P2-34100-3HF4B10183
ModelHPAmpsFrame Size
P2-26010-3H04B12.12
P2-26020-3H04B23.12
P2-26030-3H04B34.12
P2-26050-3H04B56.52
P2-26075-3H04B7.592
P2-36100-3H04B10123
P2-36150-3H04B15173
ModelMotor Output RatingDrive SizeOutput CurrentData sheet
200-240 V, 1-ph in
P2-22010-1HF4B-T1 HP (0.75 kW)24.3 APDF
P2-22020-1HF4B-T2 HP (1.5 kW)27 APDF
P2-22030-1HF4B-T3 HP (2.2 kW)210.5 APDF
P2-32050-1HF4B-T5 HP (4 kW)315.3 APDF
P2-42075-1H04B-T7.5 HP (5.5 kW)424 APDF
P2-42100-1H04B-T10 HP (7.5 kW)430 APDF
200-240 V, 3-ph in
P2-22010-3HF4B-T1 HP (0.75 kW)24.3 APDF
P2-22020-3HF4B-T2 HP (1.5 kW)27 APDF
P2-22030-3HF4B-T3 HP (2.2 kW)210.5 APDF
P2-32050-3HF4B-T5 HP (4 kW)318 APDF
P2-32075-3HF4B-T7.5 HP (5.5 kW)324 APDF
P2-42100-3HF4B-T10 HP (7.5 kW)430 APDF
P2-42150-3HF4B-T15 HP (11 kW)446 APDF
380-480 V, 3-ph in
P2-24010-3HF4B-T1 HP (0.75 kW)22.2 APDF
P2-24020-3HF4B-T2 HP (1.5 kW)24.1 APDF
P2-24030-3HF4B-T3 HP (2.2 kW)25.8 APDF
P2-24050-3HF4B-T5 HP (4 kW)29.5 APDF
P2-34075-3HF4B-T7.5 HP (5.5 kW)314 APDF
P2-34100-3HF4B-T10 HP (7.5 kW)318 APDF
P2-34150-3HF4B-T15 HP (11 kW)324 APDF
P2-44200-3HF4B-T20 HP (15 kW)430 APDF
P2-44250-3HF4B-T25 HP (18.5 kW)439 APDF
P2-44300-3HF4B-T30 HP (22 kW)446 APDF
500-600 V, 3-ph in
P2-26010-3H04B-T1 HP (0.75 kW)22.1 APDF
P2-26020-3H04B-T2 HP (1.5 kW)23.1 APDF
P2-26030-3H04B-T3 HP (2.2 kW)24.1 APDF
P2-26050-3H04B-T5 HP (4 kW)26.5 APDF
P2-26075-3H04B-T7.5 HP (5.5 kW)29 APDF
P2-36100-3H04B-T10 HP (7.5 kW)312 APDF
P2-36150-3H04B-T15 HP (11 kW)317 APDF
P2-36200-3H04B-T20 HP (15 kW)322 APDF
P2-46250-3H04B-T25 HP (18.5 kW)428 APDF
P2-46300-3H04B-T30 HP (22 kW)434 APDF
P2-46400-3H04B-T40 HP (30 kW)441 APDF

Unswitched

with keypad & display

P2 Series - AC Systems Vector Drives - NEMA 4X (IP66) | Size 2 | Unswitched - version with keypad & display
ModelHPAmpsFrame Size
P2-22010-1HF4A14.32
P2-22020-1HF4A272
P2-22030-1HF4A310.52
ModelHPAmpsFrame Size
P2-22010-3HF4A14.32
P2-22020-3HF4A272
P2-22030-3HF4A310.52
P2-32050-3HF4A5183
ModelHPAmpsFrame Size
P2-24010-3HF4A12.22
P2-24020-3HF4A24.12
P2-24030-3HF4A35.82
P2-24050-3HF4A59.52
P2-34075-3HF4A7.5143
P2-34100-3HF4A10183
ModelHPAmpsFrame Size
P2-26010-3H04A12.12
P2-26020-3H04A23.12
P2-26030-3H04A34.12
P2-26050-3H04A56.52
P2-26075-3H04A7.592
P2-36100-3H04A10123
P2-36150-3H04A15173
ModelMotor Output RatingDrive SizeOutput CurrentData sheet
200-240 V, 1-ph in
P2-22010-1HF4A-T1 HP (0.75 kW)24.3 APDF
P2-22020-1HF4A-T2 HP (1.5 kW)27 APDF
P2-22030-1HF4A-T3 HP (2.2 kW)210.5 APDF
P2-32050-1HF4A-T5 HP (4 kW)315.3 APDF
P2-42075-1H04A-T7.5 HP (5.5 kW)424 APDF
P2-42100-1H04A-T10 HP (7.5 kW)430 APDF
200-240 V, 3-ph in
P2-22010-3HF4A-T1 HP (0.75 kW)24.3 APDF
P2-22020-3HF4A-T2 HP (1.5 kW)27 APDF
P2-22030-3HF4A-T3 HP (2.2 kW)210.5 APDF
P2-32050-3HF4A-T5 HP (4 kW)318 APDF
P2-32075-3HF4A-T7.5 HP (5.5 kW)324 APDF
P2-42100-3HF4A-T10 HP (7.5 kW)430 APDF
P2-42150-3HF4A-T15 HP (11 kW)446 APDF
380-480 V, 3-ph in
P2-24010-3HF4A-T1 HP (0.75 kW)22.2 APDF
P2-24020-3HF4A-T2 HP (1.5 kW)24.1 APDF
P2-24030-3HF4A-T3 HP (2.2 kW)25.8 APDF
P2-24050-3HF4A-T5 HP (4 kW)29.5 APDF
P2-34075-3HF4A-T7.5 HP (5.5 kW)314 APDF
P2-34100-3HF4A-T10 HP (7.5 kW)318 APDF
P2-34150-3HF4A-T15 HP (11 kW)324 APDF
P2-44200-3HF4A-T20 HP (15 kW)430 APDF
P2-44250-3HF4A-T25 HP (18.5 kW)439 APDF
P2-44300-3HF4A-T30 HP (22 kW)446 APDF
500-600 V, 3-ph in
P2-26010-3H04A-T1 HP (0.75 kW)22.1 APDF
P2-26020-3H04A-T2 HP (1.5 kW)23.1 APDF
P2-26030-3H04A-T3 HP (2.2 kW)24.1 APDF
P2-26050-3H04A-T5 HP (4 kW)26.5 APDF
P2-26075-3H04A-T7.5 HP (5.5 kW)29 APDF
P2-36100-3H04A-T10 HP (7.5 kW)312 APDF
P2-36150-3H04A-T15 HP (11 kW)317 APDF
P2-36200-3H04A-T20 HP (15 kW)322 APDF
P2-46250-3H04A-T25 HP (18.5 kW)428 APDF
P2-46300-3H04A-T30 HP (22 kW)434 APDF
P2-46400-3H04A-T40 HP (30 kW)441 APDF


NEMA 1 (IP20) Units to 400HP

Bardac_AC_Drive_P2_IP20_Size8_LF_web-2022

ModelHPAmpsFrame Size
P2-84300-3HF423003708
P2-84400-3HF423504508
For single phase supply derate to 50%

Dimensions

Frame Size2233456788
ProtectionIP20NEMA 4X (IP66)IP20NEMA 4X (IP66)NEMA 12 (IP55)NEMA 12 (IP55)NEMA 12 (IP55)NEMA 12 (IP55)IP20NEMA 12 (IP55)
Height (ins)8.7”10.1”10.3”12.2”17.7”21.3”34.1”50.4”38.4”52.5”
Height (mm)22125726131045054086512809741334
Width (ins)4.4”7.4”5.2”8.3”6.8”9.3”13”13”17.5”17.5”
Width (mm)112188131211171235330330444444
Depth (ins)7.3”9.4”8.1”10.5”9.9”10.7”13.0”14.2”16.7”16.7”
Depth (mm)185239205266252270330360423423
Weight (lbs)410.67.71725.450.7121196.2274.5317.5
Weight (kg)1.84.83.57.711.5235589124.5144

Images

Downloads


To download P2 Series manuals, drawings, and more, please make a selection from the dropdown menu below:
Filename / LinkSize
Bardac_AN-P2-001_Setting-Motor-Nameplate-Details.pdf641.12 Kb
Bardac_AN-P2-002_Setting-Up-Acceleration-and-Deceleration-Ramp-Rates.pdf418.89 Kb
Bardac_AN-P2-003_Selecting-the-Required-Stopping-Mode.pdf104.45 Kb
Bardac_AN-P2-004_Locking-Parameters-to-Prevent-Changes.pdf212.38 Kb
Bardac_AN-P2-005_Displaying-Motor-Speed-in-RPM.pdf232.46 Kb
Bardac_AN-P2-006_Configuring-Voltage-and-Current-Reference-Inputs.pdf945.04 Kb
Bardac_AN-P2-007_Using_the_Skip_Frequency_Function.pdf262.09 Kb
Bardac_AN-P2-008_Selecting-the-Start-Restart-Mode.pdf103.95 Kb
Bardac_AN-P2-009_Programming-the-Drive-User-Relays.pdf195.46 Kb
Bardac_AN-P2-010_Additional-Relay-Output-Option-Modules.pdf782.33 Kb
Bardac_AN-P2-011_Using-the-Display-Scaling-Function.pdf711.96 Kb
Bardac_AN-P2-012_Using-Standby-Mode.pdf95.12 Kb
Bardac_AN-P2-015_Modifying-the-Constant-VF-Output-Characteristic.pdf847.14 Kb
Bardac_AN-P2-021_Setting-Up-Preset-Speeds.pdf4.07 Mb
Bardac_AN-P2-024_Energy-Optimization-Function.pdf987.57 Kb
Bardac_AN-P2-025_Remote-Push-Button-Speed-Control.pdf1.02 Mb
Bardac_AN-P2-027_Master-Slave-Network-Operation.pdf349.96 Kb
Bardac_AN-P2-034_Hoist-Applications_v1.01.pdf630.39 Kb
Bardac_AN-P2-034_Using-Hoist-Mode.pdf471.09 Kb
Bardac_AN-P2-038_Modbus_RTU_Control_and_Register_Map.pdf2.87 Mb
Bardac_AN-P2-045_Using-Multiple-Motors-in-Parallel.pdf2.02 Mb
Bardac_AN-P2-050_Permanent-Magnet-and-Brushless-DC-Motor-Setup.pdf174.8 Kb
Bardac_AN-P2-058_Encoder-less-Vector-Control-for-3-Phase-Induction-Motors.pdf821.46 Kb
Bardac_AN-P2-059_CAN-Bus-Operation.pdf1.06 Mb
Bardac_AN-P2-060_Drives-on-Generator-Supplies.pdf682.77 Kb
Bardac_AN-P2-063_High-Frequency-Firmware_v3.pdf270.23 Kb
Bardac_AN-P2-070_Mounting-Drives-In-Control-Panels.pdf1.38 Mb

This content is password protected. Please fill out the form below or enter the password to access.

OR

This content is password protected. Please fill out the form below or enter the password to access.

OR

This content is password protected. Please fill out the form below or enter the password to access.

OR

This content is password protected. Please fill out the form below or enter the password to access.

OR

This content is password protected. Please fill out the form below or enter the password to access.

OR